ML Reads

Personal arXiv list

ML papers to read today.

Pick a topic and keep a small daily list of papers worth opening.

Refresh queueDaily mix

Today's queue

5 papers

#01Aug 6, 2026

cs.CV

Bar-JEPA: Extracting Values from Bar Chart with Joint-Embedding Predictive Architecture

Poonam Poonam, Alexander Epple, Timo Ropinski

Bar charts are commonly used in data visualization, and while they are easily understood by humans, it is non-trivial to extract the underlying data computationally. For a machine-learning-based approach, training chart de-rendering models usually requires labeled, real-world data. Labeling data is a time consuming task, which is why annotated data is scarce. Models can learn more efficiently when provided with features of high semantic quality, which a joint-embedding predictive architecture (JEPA) is designed to learn in a self-supervised manner. We present a per-bar, numerical value recovery pipeline for bar charts, where a JEPA encoder is used to produce semantically rich latent features. The decoder model consuming these features is simple and quick to train and outputs the coordinates of ticks and bars, which can be used to recover bar values. The effectiveness of self-supervised finetuning and quality of the extracted features is evident when comparing our model to end-to-end supervised baselines. Code, datasets and checkpoints are available on \href{https://github.com/dralois/Bar-JEPA}{GitHub}.

#02Aug 6, 2026

cs.AI

Integrating Implicit and Explicit Relational Biases through Graph-Based Multiple Instance Learning: A Case Study in Skin Lesion Diagnosis

Rafał Buler, Jakub Buler, Maciej Bobowicz and 1 more

Relational inductive biases are essential for capturing structural dependencies among data. This study investigates a dual-level relational framework for image classification, bridging the gap between implicit representation learning and explicit structural modelling. We begin by establishing a baseline using an EfficientNetB3 architecture. To move beyond standard convolutional biases, we adopt a patch-based strategy, employing a convolutional masked autoencoder to learn implicit inter-patch relationships through self-supervised reconstruction. We then extend this approach by incorporating explicit relational modelling, organizing the learned embeddings into various graph topologies, including grid-based, random, and k-nearest neighbour structures. Experimental results on the ISIC-2018 and ISIC-2019 skin lesion diagnosis benchmarks show that combining implicit inter-patch modelling with explicit graph-based message passing yields the best performance. On the ISIC-2018 test set, the baseline model achieves a balanced accuracy of 76.17%, which improves to 77.12% with implicit patch-based relational modelling. The fully integrated grid-structured Graph Attention Network further increases performance to 79.27%. Similarly, on ISIC-2019, the implicit approach reaches 59.84% balanced accuracy, while the combination of implicit and explicit modelling yields 60.67%.

#03Aug 6, 2026

cs.CV

EvReflection: Event-Driven Micro-Dynamics for Reflection Removal

Jiaxiao Wang, Dachun Kai, Huyue Zhu and 3 more

Despite remarkable progress in reflection removal, current methods primarily exploit static image priors from a single frame and still suffer from severe residual artifacts due to the inherent ambiguity between the reflection and transmission layers. In this paper, we propose leveraging event signals to break this ambiguity. By employing event cameras to capture micro-dynamics, we reveal the differential motion between these two layers. We thereby present a novel event-driven reflection removal network, EvReflection, that utilizes these dynamic cues for layer separation. Specifically, we design a Micro-Dynamics Decoupler to disentangle layer-specific motions from event streams as priors, which then guide a Parallax-Attention Rectifier to cleanly remove artifacts from the RGB image. Furthermore, to address data scarcity, we develop a parallax-aware simulation pipeline and construct the EVR$^2$ benchmark dataset, the first real-world dataset for this task. Extensive experiments demonstrate that EvReflection achieves state-of-the-art performance on both synthetic and real-world benchmarks, surpassing the best competing method by more than 1.6 dB and 1.2 dB in PSNR, respectively. The code, dataset, and pre-trained models are available at https://github.com/JiaxiaoWang/EvReflection.

#04Aug 6, 2026

cs.CV

TLNM: Externally Validated Tooth Detection, Numbering and Segmentation from Smartphone Photographs Using Mask R-CNN

Arash Nedaei, Henna Tiensuu, Elina Väyrynen and 2 more

Oral health issues affect billions globally, but the cost and limited access to professional dental care hinder preventive oral healthcare. Research relies on clinical-grade radiographs or intraoral camera images, unavailable for public self-screening. This study introduces a tooth localisation and numbering model for smartphone photographs. We developed a customised Mask Region-based Convolutional Neural Network (Mask R-CNN) pipeline trained on 1,272 annotated smartphone images. To address variability in patient-generated health data, the pipeline incorporates two domain-informed mechanisms: a masked gray-world white-balancing algorithm to mitigate artificial colour casts and an anatomically constrained detection layer to enforce structural validity and suppress false positives. Evaluation comprised four stages: internal held-out testing, independent external testing, a descriptive ablation study, and fold-based training stability analysis using the same internal test set. On the internal test set, the model achieved an instance-mask AP@50 of 0.818, class-aware PQ of 0.780, and operational F1 of 0.884. Training stability showed limited between-model variation: across ten runs, instance-mask AP@50 had a standard deviation of 0.009. On the external dataset, the model achieved an instance-mask AP@50 of 0.901, class-aware PQ of 0.832, and operational F1 of 0.928 despite differences in population, sensors, and acquisition protocols. The inference pipeline is available as an open-source, containerised API. These results demonstrate that consumer-grade smartphone imagery can support automated tooth-level anatomical mapping, offering a scalable, potentially low-cost foundation for remote screening and tele-dentistry in resource-constrained environments.

#05Aug 6, 2026

cs.CV

Does FLAIR super-resolution erase or hallucinate small white-matter lesions?

Zahra Khodakarami, Yue Li, Pulkit Khandelwal and 5 more

White matter hyperintensities (WMH), bright regions on Fluid-attenuated Inversion Recovery (FLAIR) scans are associated with cerebrovascular pathology and neurodegeneration. FLAIR is usually acquired with thick slices in clinical settings, giving it poor through-plane resolution. Super-resolution (SR) is a widely used method for recovering an isotropic volume from an anisotropic scan. Yet whether applying it prior to WMH segmentation preserves lesion content remains unknown: a model may erase small real lesions or hallucinate absent ones. We used 1-mm isotropic high-resolution (HR) FLAIR scans from 29 individuals in the ADNI cohort, each manually segmented for WMH by an expert. Then, we degraded each to simulated 3 and 5 mm through-plane acquisitions. Multi-contrast implicit neural representation (INR), a single-contrast self-supervised model (ECLARE), and cubic interpolation were used to upsample them onto the HR grid. WMH segmentation from a simulated thick slice and the original HR FLAIR set the floor and ceiling, respectively, for the per-lesion analysis. Of four WMH segmentation methods (WMH-SynthSeg, segcsvd, MARS-WMH, TrUE-Net), we ran the analysis under the most sensitive one to small lesions on HR (MARS-WMH) with the evaluation metrics of detection sensitivity, erasure rate (HR-detected lesions lost after reconstruction), and hallucination rate (predicted components absent from both the manual and HR segmentation). The dominant effect of SR was erasure of small real lesions, not hallucination, and it increased with slice thickness, though every reconstruction still improved lesion detection over the raw thick slice. ECLARE recovered small lesion signal best at both thicknesses, while the INR was no better than cubic interpolation.