#01Aug 6, 2026
cs.CV
Does FLAIR super-resolution erase or hallucinate small white-matter lesions?
Zahra Khodakarami, Yue Li, Pulkit Khandelwal and 5 more
White matter hyperintensities (WMH), bright regions on Fluid-attenuated Inversion Recovery (FLAIR) scans are associated with cerebrovascular pathology and neurodegeneration. FLAIR is usually acquired with thick slices in clinical settings, giving it poor through-plane resolution. Super-resolution (SR) is a widely used method for recovering an isotropic volume from an anisotropic scan. Yet whether applying it prior to WMH segmentation preserves lesion content remains unknown: a model may erase small real lesions or hallucinate absent ones. We used 1-mm isotropic high-resolution (HR) FLAIR scans from 29 individuals in the ADNI cohort, each manually segmented for WMH by an expert. Then, we degraded each to simulated 3 and 5 mm through-plane acquisitions. Multi-contrast implicit neural representation (INR), a single-contrast self-supervised model (ECLARE), and cubic interpolation were used to upsample them onto the HR grid. WMH segmentation from a simulated thick slice and the original HR FLAIR set the floor and ceiling, respectively, for the per-lesion analysis. Of four WMH segmentation methods (WMH-SynthSeg, segcsvd, MARS-WMH, TrUE-Net), we ran the analysis under the most sensitive one to small lesions on HR (MARS-WMH) with the evaluation metrics of detection sensitivity, erasure rate (HR-detected lesions lost after reconstruction), and hallucination rate (predicted components absent from both the manual and HR segmentation). The dominant effect of SR was erasure of small real lesions, not hallucination, and it increased with slice thickness, though every reconstruction still improved lesion detection over the raw thick slice. ECLARE recovered small lesion signal best at both thicknesses, while the INR was no better than cubic interpolation.
#02Aug 6, 2026
cs.CV
PaCoNet: Deep Data Extraction for Parallel Coordinates
Poonam Poonam, Hannah Kniesel, Pere-Pau Vázquez and 1 more
Extracting data from visualizations has long challenged computer vision, with current research focused on bar, line, and pie charts, among other low-dimensional visualizations. However, parallel coordinates as a widely used high-dimensional data visualization approach, remain largely unexplored in this context. As parallel coordinate plots can quickly become cluttered and difficult to interpret when poorly designed or densely populated, automated data extraction from such visualizations is of particular interest. In this paper, we propose PaCoNet, the first approach for parallel coordinate data extraction. PaCoNet not only extracts line coordinates, but also enables the extraction of individual data samples for further analysis. Towards this end, we make the following contributions. We present the first deep learning approach tailored for parallel coordinate analysis, and demonstrate that it outperforms unadapted baselines by a significant margin. We further introduce a large-scale parallel coordinate dataset for training and testing. Together, these key contributions enable for the first time the automated analysis and redesign of parallel coordinate plots. PaCoNet thus lays the groundwork for complex visualization analysis, and further advances the intersection of computer vision and data visualization. All code, trained models, and data generation scripts will be made publicly available upon acceptance of the paper.
#03Aug 6, 2026
cs.CV
Depth-Guided Video Object Counting in Crowded Scenes
Yuanjing Xu, Xinyan Liu, Weidong Chen and 5 more
Our primary objective is to advance video object counting in crowded scenes, aiming to robustly count all instances of a target category based on given text or visual prompts. Existing methods rely on RGB information, limiting their discriminative ability in crowded and occluded conditions. To address this, we propose a Depth-Guided Detector (DG-Det) along with a general post-processing pipeline. By integrating depth cues with multi-scale RGB-D cross-attention and explicit occlusion prediction, our method enhances spatial understanding and achieves robust detection in crowded and occluded scenes. Furthermore, we introduce a unified de-duplication framework to eliminate cross-frame redundant counting. To facilitate future research, we also release a new RGB-D Video Object Counting dataset featuring depth information and multiple object categories persequence. Extensive experiments demonstrate that our method achieves a 62.01\% reduction in MAE compared to existing baselines, and also produces consistent improvements in RMSE. We provide the source code at https://github.com/streamer-AP/DG-Net and the dataset at https://huggingface.co/datasets/aerospace123/RGBD-VideoCount.
#04Aug 6, 2026
cs.CV
TLNM: Externally Validated Tooth Detection, Numbering and Segmentation from Smartphone Photographs Using Mask R-CNN
Arash Nedaei, Henna Tiensuu, Elina Väyrynen and 2 more
Oral health issues affect billions globally, but the cost and limited access to professional dental care hinder preventive oral healthcare. Research relies on clinical-grade radiographs or intraoral camera images, unavailable for public self-screening. This study introduces a tooth localisation and numbering model for smartphone photographs. We developed a customised Mask Region-based Convolutional Neural Network (Mask R-CNN) pipeline trained on 1,272 annotated smartphone images. To address variability in patient-generated health data, the pipeline incorporates two domain-informed mechanisms: a masked gray-world white-balancing algorithm to mitigate artificial colour casts and an anatomically constrained detection layer to enforce structural validity and suppress false positives. Evaluation comprised four stages: internal held-out testing, independent external testing, a descriptive ablation study, and fold-based training stability analysis using the same internal test set. On the internal test set, the model achieved an instance-mask AP@50 of 0.818, class-aware PQ of 0.780, and operational F1 of 0.884. Training stability showed limited between-model variation: across ten runs, instance-mask AP@50 had a standard deviation of 0.009. On the external dataset, the model achieved an instance-mask AP@50 of 0.901, class-aware PQ of 0.832, and operational F1 of 0.928 despite differences in population, sensors, and acquisition protocols. The inference pipeline is available as an open-source, containerised API. These results demonstrate that consumer-grade smartphone imagery can support automated tooth-level anatomical mapping, offering a scalable, potentially low-cost foundation for remote screening and tele-dentistry in resource-constrained environments.
#05Aug 6, 2026
cs.CV
HOPE: Hand-Object Pressure Estimation from Monocular Videos
Subin Jeon, Byungjun Kim, Hanbyul Joo
Estimating physical pressure from vision is essential for understanding contact-rich hand-object interaction. However, prior vision-based pressure estimation methods are largely limited to planar surfaces and single image input, making them difficult to apply to dynamic hand-object interaction with diverse objects. We instead formulate pressure estimation as a hand-centric video prediction problem with monocular video as input. This formulation predicts temporally evolving per-vertex normal pressure and contact directly on the hand mesh, yielding a unified output space independent of object shape and sensor layout. Building on this formulation, we propose \textbf{HOPE}, a framework with two key components. First, we lift tactile-glove pressure, planar-sensor pressure, and distance-based hand-object contact annotations into a shared hand vertex space, allowing bare-hand contact data to regularize pressure learning where metric labels are unavailable. Second, we introduce a vertex-anchored video transformer that treats each vertex as a persistent token, aggregates visual features and hand pose over time, and uses a contact-gated pressure head to enforce that pressure vanishes without contact. Experiments on OpenTouch, PressureVisionDB, and hand-object contact benchmarks validate HOPE across object-pressure, surface-pressure, and contact-supervised HOI settings. Despite using metric pressure supervision primarily from gloved-hand videos, HOPE generalizes to bare-hand egocentric and in-the-wild videos, producing joint contact and pressure predictions beyond the scope of contact-only or planar-pressure baselines.