#01Aug 6, 2026
cs.CV
TLNM: Externally Validated Tooth Detection, Numbering and Segmentation from Smartphone Photographs Using Mask R-CNN
Arash Nedaei, Henna Tiensuu, Elina Väyrynen and 2 more
Oral health issues affect billions globally, but the cost and limited access to professional dental care hinder preventive oral healthcare. Research relies on clinical-grade radiographs or intraoral camera images, unavailable for public self-screening. This study introduces a tooth localisation and numbering model for smartphone photographs. We developed a customised Mask Region-based Convolutional Neural Network (Mask R-CNN) pipeline trained on 1,272 annotated smartphone images. To address variability in patient-generated health data, the pipeline incorporates two domain-informed mechanisms: a masked gray-world white-balancing algorithm to mitigate artificial colour casts and an anatomically constrained detection layer to enforce structural validity and suppress false positives. Evaluation comprised four stages: internal held-out testing, independent external testing, a descriptive ablation study, and fold-based training stability analysis using the same internal test set. On the internal test set, the model achieved an instance-mask AP@50 of 0.818, class-aware PQ of 0.780, and operational F1 of 0.884. Training stability showed limited between-model variation: across ten runs, instance-mask AP@50 had a standard deviation of 0.009. On the external dataset, the model achieved an instance-mask AP@50 of 0.901, class-aware PQ of 0.832, and operational F1 of 0.928 despite differences in population, sensors, and acquisition protocols. The inference pipeline is available as an open-source, containerised API. These results demonstrate that consumer-grade smartphone imagery can support automated tooth-level anatomical mapping, offering a scalable, potentially low-cost foundation for remote screening and tele-dentistry in resource-constrained environments.
#02Aug 6, 2026
cs.CV
PRISM: Distribution-Gated Flow Matching for Controllable Unpaired Image Translation
Elad Yoshai, Natan T. Shaked
Unpaired image-to-image translation must decide, per image, what to change and what to preserve without paired supervision. Many diffusion-based unpaired translators control preservation through a single global noise or guidance value applied across the image, which cannot separate content to keep from appearance to change. We present PRISM, a GAN-free flow-matching framework that replaces this global control with a learned per-feature gate. The gate's spatial prior is derived from each source feature's standardized distance to the target feature distribution, so features far from the target are freed while target-consistent features are preserved. The same gate controls both the initialization, which mixes the real source latent with a task-matched corruption, and the transport timing during Ordinary Differential Equation (ODE) integration. The corruption is matched to the task, content-anchored (AdaIN) for structure-preserving translation and partially anchored for structure-changing translation, and the gate can be overridden locally at inference from text or a detector without retraining, preserving important structures of the original image while still generating realistic results. We evaluate PRISM on five natural and biomedical benchmarks (AFHQ cat->dog, CelebA-HQ appearance translation, day->night relighting, virtual staining, and breast frozen->permanent histopathology). Among the evaluated methods under a shared same-split protocol, PRISM attains the best Inception FID and KID on four benchmarks and a competitive result on the fifth, and on histopathology yields the nuclei-count ratio closest to the ideal, supporting a favorable balance between target realism and structural preservation.
#03Aug 6, 2026
cs.CV
HOPE: Hand-Object Pressure Estimation from Monocular Videos
Subin Jeon, Byungjun Kim, Hanbyul Joo
Estimating physical pressure from vision is essential for understanding contact-rich hand-object interaction. However, prior vision-based pressure estimation methods are largely limited to planar surfaces and single image input, making them difficult to apply to dynamic hand-object interaction with diverse objects. We instead formulate pressure estimation as a hand-centric video prediction problem with monocular video as input. This formulation predicts temporally evolving per-vertex normal pressure and contact directly on the hand mesh, yielding a unified output space independent of object shape and sensor layout. Building on this formulation, we propose \textbf{HOPE}, a framework with two key components. First, we lift tactile-glove pressure, planar-sensor pressure, and distance-based hand-object contact annotations into a shared hand vertex space, allowing bare-hand contact data to regularize pressure learning where metric labels are unavailable. Second, we introduce a vertex-anchored video transformer that treats each vertex as a persistent token, aggregates visual features and hand pose over time, and uses a contact-gated pressure head to enforce that pressure vanishes without contact. Experiments on OpenTouch, PressureVisionDB, and hand-object contact benchmarks validate HOPE across object-pressure, surface-pressure, and contact-supervised HOI settings. Despite using metric pressure supervision primarily from gloved-hand videos, HOPE generalizes to bare-hand egocentric and in-the-wild videos, producing joint contact and pressure predictions beyond the scope of contact-only or planar-pressure baselines.
#04Aug 6, 2026
cs.CV
Toward Deployable Bangla Sign Language Recognition with Expert-Validated Data and a Lightweight Attention-Based Model
Saad Ahmed, Md Khalid Syfullaha
Deaf and hard-of-hearing people in Bangladesh communicate mainly through Bangla Sign Language (BdSL). Automatic BdSL recognition on personal devices could widen access to education and services. Existing systems use controlled-setting datasets without expert verification and heavyweight pretrained backbones unsuited to on-device use. We introduce RSBdSL38, 10,874 expert-validated images spanning all 38 BdSL hand signs, representing the 51 letters of the Bangla alphabet, recorded from real signers at three special-needs schools across Bangladesh. We propose a lightweight attention based convolutional network of 298,470 parameters, built from grouped bottleneck residual blocks, channel and spatial attention, a multi-scale depthwise hand-feature block, dual pooling, and Swish activations. Trained from scratch, it attains 96.37% accuracy (95.72% +- 0.54% over five seeds), within 1.08 percentage points of the best of nine ImageNet-pretrained efficient architectures under an identical protocol, using 8.5 to 68x fewer parameters and 1.3 to 21.7x fewer MACs. Retrained, it reaches 92.95 to 98.33% on six public BdSL benchmarks, 97.04% on a merged corpus, and 76.25% zero-shot on BdSL-38. Removing any architectural stage costs 7.61 to 89.30 points, against at most 3.17 for the training recipe. Grad-CAM with deletion-insertion and weight-randomization checks confirms that predictions follow the signing hand. A signer-independent split holding out 6 of 36 signers yields 85.18%. Quantized to 0.48 MB, it runs at 3.98 ms per image within a 15.5 MB footprint on a commodity smartphone. Together, RSBdSL38 and our from-scratch model turn benchmark accuracy into deployable accessibility at a fraction of pretrained-backbone cost; dataset, code, and models are released.
#05Aug 6, 2026
cs.CV
Patient Pose Assessment Using a CT-Based Framework for Synthetic Data Generation
Manuel Laufer, Dominik Mairhöfer, Malte Sieren and 7 more
An adequate diagnostic quality of radiographs is essential for reliable diagnoses and treatment planning. The patient's pose during radiography is one of the most important factors determining the diagnostic quality. Since patient positioning is difficult and not standardized, an automated AI-based approach using depth images to automatically assess the patient's pose before the radiograph has been taken would be helpful. Due to regulatory hurdles, however, it is difficult in practice to acquire the required depth images and corresponding radiographs. In this paper, we present a framework that can generate such training data synthetically from Computed Tomography scans. We further show that by pretraining on our generated synthetic dataset consisting of 3077 image pairs of upper ankle joints, the pose assessment of real upper ankle joints can be improved by up to 11 percentage points.